[email protected] | +65 9890 3047 / +65 8575 7421 | Singapore — 24hr OMD Supply Available
Authorized Dealer 24hr Ex-Stock Supply Singapore

Oil Mist Detector
Solutions

Singapore's trusted authorized supplier of all major OMD brands. We supply, service and calibrate oil mist detection systems for marine, offshore and industrial engines — 24 hours after Purchase Order.

🔴
Kidde Graviner
MK6 / MK7 — UK
🟠
Schaller Visatron
VN115 / VN215 — Germany
🟡
SPECS Vision
AOMD / COMD — Korea
🔵
Daihatsu OMD
MD-SX / MD-9M — Japan
Authorized DealersAll Major Brands
24-Hour SupplyAfter PO Confirmation
Factory-TrainedWorkshop Technicians
1-Year WarrantyAll Supplied Equipment
Exchange OfferRefurbished OMDs Available
About Us

What Is an Oil Mist Detector?

Oil Mist Detector System for Marine Engines
Singapore Authorized Dealer

Oil mist is a tiny droplet of oil suspended in the air — considered extremely hazardous due to its low ignition temperature, creating a serious fire and explosion risk in engine crankcases and machinery spaces.

The most common cause of oil mist formation is oil leakage from pressurized oil lines, or oil hitting hot surfaces causing rapid evaporation. Oil leakages frequently occur in engine rooms, pump rooms, and hydraulic installations.

By installing an oil mist detector, dangerous concentrations are detected and alarmed before reaching the lower explosion limit — protecting both crew and vessel from catastrophic crankcase explosions.

We are the authorized dealers for all well-known OMD brands, maintaining a large inventory of OMDs and spare parts. We ensure the best possible economical quality solutions for ship managers.

  • Authorized dealers — Kidde Graviner, Schaller, SPECS, Daihatsu
  • Large ex-stock inventory in Singapore
  • 1-year warranty on all supplied equipment
  • Rigorous testing by factory-trained technicians
  • Bulk quantity and annual service contracts available
  • 24-hour supply after receipt of Purchase Order
Our Brands

Authorized OMD Brands We Supply

We stock and service all major oil mist detector brands used in marine and industrial engines worldwide.

KG

Kidde Graviner

United Kingdom — Part of UTC Fire & Security
MK6MK7MK5 (Surplus)
Kidde Graviner Oil Mist Detector MK6 MK7

The Graviner Mk6 is an advanced analogue addressable oil mist detection system monitoring up to 64 detector heads and 8 engines. Detects average crankspace oil mist densities between 0.3–1.3 mg/L. Less than 1.2 seconds scan time for a 64-detector system. Microprocessor electronics ensure a very high degree of active fault indication.

The Graviner MK7 is the next-generation model offering improved digital communication, enhanced display and reduced maintenance intervals.

ParameterMK6 Specification
Measuring Range0–30 mg/L
Ventilation TypeForced
Max Detectors64 heads / 8 engines
Scan Time (64 det.)< 1.2 seconds
Power Supply24V DC
Read More →
SV

Schaller Visatron

Germany — Schaller Automation
VN 115/87 PlusVN 215/87 PlusVN 215/93VN2020
Schaller Visatron VN115 VN215 Oil Mist Detector

VISATRON uses infrared turbidity measurement with a wear-free air jet pump powered by compressed air for continuous oil mist detection. The system continuously and simultaneously evacuates crankcase atmosphere from every compartment — measuring turbidity as % Opacity (0% = no absorption, 100% = total absorption).

Built to last for the entire engine lifetime with extremely low maintenance costs. Fresh air chambers provide active dirt protection for optics. Approved by 11 classification societies.

ParameterVN 215/93 Specification
Measuring Range0.2–50 mg/L
Ventilation TypeForced (air jet pump)
Detection MethodInfrared turbidity (% Opacity)
Classification11 societies approved
Read More →
SP

SPECS Vision

Korea — SPECS Corporation
AOMD (Atmospheric)COMD (Crankcase)Vision III A/C
SPECS Vision AOMD COMD Oil Mist Detector Korea

SPECS is Korea's unique and leading specialist in oil mist detection for marine engines. The SPECS Vision AOMD (Atmospheric Oil Mist Detector) accurately detects and activates alarms when oil mist is present in a marine engine crankcase or in closed room conditions. Far superior to other OMDs from the worldwide market.

COMD (Crankcase OMD) monitors individual crankcase compartments. Suitable for shipbuilding, LNG tanks, telecommunications and industrial applications.

ParameterVision III C Specification
Measuring Range0–2.5 mg/L
TypeAOMD / COMD
OriginKorea (SPECS Corp.)
ApplicationMarine, LNG, Industrial
Read More →
DH

Daihatsu OMD

Japan — Daihatsu Diesel Mfg. Co. Ltd
MD-SXMD-9M
Daihatsu Oil Mist Detector MD-SX MD-9M Japan

Daihatsu OMD uses an optical dispersion system with natural ventilation — no suction mechanism or fan required. The MD-SX model is widely used on Daihatsu auxiliary engines and main engines across all vessel types including tankers, bulkers, container ships and naval vessels.

The MD-9M and MD-SX models provide reliable crankcase monitoring and quick alarm activation upon detection of dangerous oil mist concentrations.

ParameterMD-SX Specification
Measuring Range0–2 mg/L
Ventilation TypeNatural (no fan/suction)
Detection MethodOptical dispersion
CompatibilityDaihatsu main/aux engines
Read More →
Why Choose Us

The OMD Experts in Singapore

🏆

Authorized Dealers

Officially authorized for Kidde Graviner, Schaller Visatron, SPECS Vision and Daihatsu OMD — ensuring 100% genuine parts and systems.

24-Hour Supply

We can supply and service all OMD equipment within 24 hours after receipt of Purchase Order confirmations — minimizing vessel downtime.

🔧

Factory-Trained Technicians

Our highly skilled workshop technicians are factory-trained by OMD manufacturers — providing expert servicing at Singapore ports.

📦

Large Ex-Stock Inventory

We maintain a large inventory of OMDs and spare parts from all major manufacturers for immediate availability.

🔄

Exchange Offer Available

Refurbished and surplus OMD units available for budget-conscious ship managers. All refurbished units pass rigorous testing before supply.

📋

Annual Service Contracts

We offer bulk quantity purchasing and annual servicing contracts for fleet operators and ship management companies.

Services

Sales, Calibration & Service

🛒

OMD Supply — Original & Refurbished

Original genuine instruments for longevity and warranty compliance. Refurbished certified units available for budget solutions.

🔬

Annual Calibration & Maintenance

Yearly calibration per manufacturer requirements at Singapore, Malaysia, Dubai/UAE and major Indian ports.

🛠️

Troubleshooting & Repair

Factory-trained technicians for on-site troubleshooting, installation guidance and workshop repairs.

📞

After-Sales Support — Short Notice

We provide after-sales support to all ships calling Singapore Ports at short notice — 24/7 availability.

We Recommend Original Genuine Instruments

For longevity and warranty compliance, we always recommend original instruments from the following reputed manufacturers:

  • Kidde Graviner MK6, MK7 (MK5 — surplus spares only)
  • SPECS Corporation Korea — Specs Vision AOMD & COMD
  • Schaller Visatron VN 115/87 Plus, VN 215/87 Plus, VN 215/93
  • Note: VN 115/87 EMC & VN 215/87 EMC are obsolete — refurbished certified units only
  • Daihatsu Diesel MD-SX, MD-9M
Request a Quote
Get In Touch

Contact OMD Solutions

📍

Address

Oil Mist Detector Solutions Pte Ltd
7 Soon Lee Street #03-40 ISpace
Singapore — 627608

Service Coverage

Singapore Ports • Malaysia • Dubai / UAE • Indian Ports
Annual calibration, maintenance & health checks available at short notice.

Enquire Now

8 + 4 =
✓ Thank you! Your enquiry has been sent. We will respond within 24 hours.

Need OMD Supply or Service Urgently?

We supply and service all OMD equipment within 24 hours after PO confirmation — Singapore ports and beyond.

📞 +65 9890 3047
Home Call Email